@@ -2,78 +2,195 @@
|
||||
|
||||
# Disaggregated Deployment
|
||||
|
||||
Large model inference consists of two phases: Prefill and Decode, which are compute-intensive and memory access-intensive respectively. Deploying Prefill and Decode separately in certain scenarios can improve hardware utilization, effectively increase throughput, and reduce overall sentence latency.
|
||||
Large Language Model (LLM) inference is divided into two phases: **Prefill** and **Decode**, which are compute-intensive and memory-bound, respectively.
|
||||
|
||||
* Prefill phase: Processes all input Tokens (such as user prompts), completes the model's forward propagation, and generates the first token.
|
||||
* Decode phase: Starting from the first generated token, it generates one token at a time autoregressively until reaching the stop token. For N output tokens, the Decode phase requires (N-1) forward propagations that must be executed serially. During generation, the number of tokens to attend to increases, and computational requirements gradually grow.
|
||||
* **Prefill Phase:** Processes all input tokens, completes the model's forward pass, and generates the first token.
|
||||
* **Decode Phase:** Generates subsequent tokens based on the first token and the cached KV Cache. Assuming a total output of N tokens, the Decode phase requires executing (N-1) forward passes.
|
||||
|
||||
The core of disaggregated deployment is to deploy Prefill and Decode on different computing resources to improve their respective utilization. To achieve disaggregated deployment, communication between Prefill and Decode must be considered.
|
||||
During actual inference, Prefill needs to transmit the computed KV Cache to the Decode instance, which then reads the KV Cache for continuation.
|
||||
Disaggregated deployment involves deploying Prefill and Decode on distinct computing resources, each using optimal configurations. This approach improves hardware utilization, increases throughput, and reduces end-to-end latency.
|
||||
|
||||
## KV Cache Transmission Methods
|
||||
We provide two transmission methods for KV Cache, targeting intra-machine and inter-machine scenarios respectively.
|
||||
<p align="center">
|
||||
<img src="../zh/features/images/mix_pd.png" width="50%">
|
||||
</p>
|
||||
|
||||
### Intra-machine Transmission
|
||||
Uses cudaMemcpyPeer for KV Cache transmission between two GPUs within a single machine, offering low latency and high throughput.
|
||||
Compared to mixed deployment, the core implementation differences of disaggregated deployment lie in **KV Cache transmission** and **request scheduling**.
|
||||
|
||||
### Inter-machine Transmission
|
||||
For transmission between multiple machines, uses high-speed RDMA network for KV Cache transmission. We provide the `rdma_comm` high-speed transmission network library for cross-machine KV Cache transmission.
|
||||
## KV Cache Transmission
|
||||
|
||||
## PD Disaggregated Scheduling
|
||||

|
||||
Building upon the global scheduler, FastDeploy supports the PD disaggregated scheduling strategy, specifically designed for large language model inference scenarios, decoupling the two phases of the inference process:
|
||||
* Prefill phase: Builds KV cache, compute-intensive, high memory usage but low latency.
|
||||
* Decode phase: Performs autoregressive decoding, serial process, time-consuming but with low memory usage.
|
||||
In disaggregated deployment, the KV Cache generated by the request in the Prefill instance needs to be transmitted to the Decode instance. FastDeploy provides two transmission methods targeting intra-node and inter-node scenarios.
|
||||
|
||||
In multi-instance scenarios, each incoming request needs to be assigned to different Prefill and Decode instances based on different strategies. Through role separation (Prefill nodes handle request reception and processing, Decode nodes complete subsequent generation), resource allocation can be more finely controlled to improve throughput and GPU utilization.
|
||||
**Intra-node transmission:** Uses `cudaMemcpyPeer` for KV Cache transmission between two GPUs within a single node.
|
||||
|
||||
**Inter-node transmission:** Uses a self-developed [RDMA transmission library](https://github.com/PaddlePaddle/FastDeploy/tree/develop/fastdeploy/cache_manager/transfer_factory/kvcache_transfer) to transfer KV Cache between multiple nodes.
|
||||
|
||||
## PD Disaggregated Request Scheduling
|
||||
|
||||
For PD (Prefill-Decode) disaggregated deployment, FastDeploy provides a Python version of the [Router](https://github.com/PaddlePaddle/FastDeploy/tree/develop/fastdeploy/router) to implement request reception and scheduling. The usage method and scheduling flow are as follows:
|
||||
|
||||
* Start the Router.
|
||||
* Start PD instances, the PD instances will register with the Router.
|
||||
* User requests are sent to the Router.
|
||||
* The Router selects a suitable PD instance pair based on the load conditions of the PD instances.
|
||||
* The Router forwards the request to the selected PD instance.
|
||||
* The Router receives the generation results from the PD instance and returns them to the user.
|
||||
|
||||
A high-performance version of the Router is currently under development. Stay tuned.
|
||||
|
||||
## Usage Instructions
|
||||
|
||||
### Multi-machine Disaggregated Deployment
|
||||
### Router-based Disaggregated Deployment
|
||||
|
||||
#### Prerequisite: Redis
|
||||
#### Environment Preparation
|
||||
|
||||
> **⚠️ NOTE**
|
||||
> **Redis requirement: version 6.2.0 or higher**
|
||||
> Versions below this may not support the required commands.
|
||||
>
|
||||
* Installation via `conda`
|
||||
Please refer to the [documentation](https://github.com/PaddlePaddle/FastDeploy/tree/develop/docs/zh/get_started/installation) to prepare the environment. Using Docker is recommended.
|
||||
If you are setting up the runtime environment manually, ensure that RDMA dependency packages (`librdmacm-dev`, `libibverbs-dev`, `iproute2`) and the [MLNX_OFED](https://network.nvidia.com/products/infiniband-drivers/linux/mlnx_ofed/) driver are installed.
|
||||
|
||||
```bash
|
||||
apt update --fix-missing
|
||||
apt-get install -y librdmacm-dev libibverbs-dev iproute2
|
||||
|
||||
# Download and install MLNX_OFED
|
||||
./mlnxofedinstall --user-space-only --skip-distro-check --without-fw-update --force --without-ucx-cuda
|
||||
|
||||
```
|
||||
|
||||
Pull the latest FastDeploy code, build, and install.
|
||||
|
||||
```bash
|
||||
git clone https://github.com/PaddlePaddle/FastDeploy
|
||||
cd FastDeploy
|
||||
bash build.sh
|
||||
|
||||
```
|
||||
|
||||
#### Deploy Services
|
||||
|
||||
**Quick Start**
|
||||
|
||||
Start the Router service. The `--splitwise` parameter specifies the scheduling mode as disaggregated deployment. Log information is output to `log_router/router.log`.
|
||||
|
||||
```bash
|
||||
export FD_LOG_DIR="log_router"
|
||||
python -m fastdeploy.router.launch \
|
||||
--host 0.0.0.0 \
|
||||
--port 30000 \
|
||||
--splitwise
|
||||
|
||||
```
|
||||
|
||||
Start the Prefill instance. Compared to single-node deployment, add the `--splitwise-role` parameter to specify the instance role as Prefill, and the `--router` parameter to specify the Router interface. Other parameters remain the same as mixed deployment.
|
||||
|
||||
```bash
|
||||
export CUDA_VISIBLE_DEVICES=0
|
||||
export FD_LOG_DIR="log_prefill"
|
||||
python -m fastdeploy.entrypoints.openai.api_server \
|
||||
--model "PaddlePaddle/ERNIE-4.5-0.3B-Paddle" \
|
||||
--port 31000 \
|
||||
--splitwise-role prefill \
|
||||
--router "0.0.0.0:30000"
|
||||
|
||||
```
|
||||
|
||||
Start the Decode instance.
|
||||
|
||||
```bash
|
||||
export CUDA_VISIBLE_DEVICES=1
|
||||
export FD_LOG_DIR="log_decode"
|
||||
python -m fastdeploy.entrypoints.openai.api_server \
|
||||
--model "PaddlePaddle/ERNIE-4.5-0.3B-Paddle" \
|
||||
--port 32000 \
|
||||
--splitwise-role decode \
|
||||
--router "0.0.0.0:30000"
|
||||
|
||||
```
|
||||
|
||||
After the Prefill and Decode instances are successfully started and registered with the Router, you can send requests.
|
||||
|
||||
```bash
|
||||
curl -X POST "http://0.0.0.0:30000/v1/chat/completions" \
|
||||
-H "Content-Type: application/json" \
|
||||
-d '{
|
||||
"messages": [
|
||||
{"role": "user", "content": "hello"}
|
||||
],
|
||||
"max_tokens": 100,
|
||||
"stream": false
|
||||
}'
|
||||
|
||||
```
|
||||
|
||||
**Details Description**
|
||||
|
||||
Parameter description for starting Prefill/Decode instances in disaggregated deployment:
|
||||
|
||||
* `--splitwise-role`: Specifies the instance role. Options are `prefill`, `decode`, and `mixed`. Default is `mixed`.
|
||||
* `--cache-transfer-protocol`: Specifies the KV Cache transfer protocol. Options are `rdma` and `ipc`. Default is `rdma` and `ipc`. If PD instances are on the same machine, `ipc` transmission is prioritized.
|
||||
* `--rdma-comm-ports`: Specifies RDMA communication ports, separated by commas. The number of ports must equal `dp_size * tp_size`. If unspecified, FD will internally find free ports.
|
||||
* `--pd-comm-port`: Specifies the interaction interface for PD instances, separated by commas. The number of ports must equal `dp_size`. If unspecified, FD will internally find free ports.
|
||||
* `--router`: Specifies the Router interface.
|
||||
|
||||
If the Prefill and Decode instances are deployed on different machines, RDMA network connectivity between the machines must be ensured.
|
||||
To manually specify RDMA network interfaces, you can set the `KVCACHE_RDMA_NICS` environment variable. Multiple NICs should be separated by commas. FastDeploy provides a script to detect RDMA NICs automatically:
|
||||
`bash FastDeploy/scripts/get_rdma_nics.sh <device>`, where `<device>` can be either `cpu` or `gpu`.
|
||||
If the `KVCACHE_RDMA_NICS` environment variable is not set, FastDeploy will automatically detect available RDMA NICs internally.
|
||||
|
||||
**Examples**
|
||||
|
||||
PD disaggregated deployment supports features such as prefix caching, Tensor Parallelism (TP), and Data Parallelism (DP). For specific examples, please refer to [examples/splitwise](https://github.com/PaddlePaddle/FastDeploy/tree/develop/examples/splitwise).
|
||||
|
||||
### SplitwiseScheduler-based Disaggregated Deployment
|
||||
|
||||
**Note: Using SplitwiseScheduler is not recommended. It is recommended to use the Router for request scheduling.**
|
||||
|
||||
#### Environment Preparation
|
||||
|
||||
* Install using `conda`
|
||||
|
||||
> **⚠️ Note**
|
||||
> **Redis Version Requirement: 6.2.0 and above**
|
||||
> Versions below this may not support required commands.
|
||||
|
||||
```bash
|
||||
# Install
|
||||
conda install redis
|
||||
# Start
|
||||
nohup redis-server > redis.log 2>&1 &
|
||||
|
||||
```
|
||||
|
||||
* Installation via `apt`
|
||||
* Install using `apt`
|
||||
|
||||
```bash
|
||||
# Install
|
||||
sudo apt install redis-server -y
|
||||
# Start
|
||||
sudo systemctl start redis-server
|
||||
|
||||
```
|
||||
|
||||
* Installation via `yum`
|
||||
* Install using `yum`
|
||||
|
||||
```bash
|
||||
# Install
|
||||
sudo yum install redis -y
|
||||
# Start
|
||||
sudo systemctl start redis
|
||||
|
||||
```
|
||||
|
||||
#### Online Inference Service
|
||||
For multi-machine deployment, confirm that the NIC supports RDMA and that all nodes in the cluster have network connectivity.
|
||||
#### Deploy Services
|
||||
|
||||
For multi-node deployment, ensure that the current network interface card supports RDMA and that all nodes in the cluster have network connectivity.
|
||||
|
||||
**Note**:
|
||||
* `KVCACHE_RDMA_NICS` specifies RDMA network cards for the current machine, multiple cards should be separated by commas.
|
||||
* The repository provides an automatic RDMA network card detection script `bash scripts/get_rdma_nics.sh <device>`, where <device> can be `cpu` or `gpu`.
|
||||
|
||||
**Prefill Instance**
|
||||
* `KVCACHE_RDMA_NICS` specifies the RDMA NICs of the current machine; separate multiple NICs with commas.
|
||||
* The repository provides a script to automatically detect RDMA NICs: `bash scripts/get_rdma_nics.sh <device>`, where `<device>` can be `cpu` or `gpu`.
|
||||
|
||||
**prefill instance**
|
||||
|
||||
```bash
|
||||
|
||||
export FD_LOG_DIR="log_prefill"
|
||||
export CUDA_VISIBLE_DEVICES=0,1,2,3
|
||||
export ENABLE_V1_KVCACHE_SCHEDULER=0
|
||||
@@ -82,8 +199,7 @@ export $(bash scripts/get_rdma_nics.sh gpu)
|
||||
echo "KVCACHE_RDMA_NICS ${KVCACHE_RDMA_NICS}"
|
||||
python -m fastdeploy.entrypoints.openai.api_server \
|
||||
--model ERNIE-4.5-300B-A47B-BF16 \
|
||||
--port 8180 \
|
||||
--metrics-port 8181 \
|
||||
--port 8180 --metrics-port 8181 \
|
||||
--engine-worker-queue-port 8182 \
|
||||
--cache-queue-port 8183 \
|
||||
--tensor-parallel-size 4 \
|
||||
@@ -95,10 +211,12 @@ python -m fastdeploy.entrypoints.openai.api_server \
|
||||
--scheduler-name "splitwise" \
|
||||
--scheduler-host "127.0.0.1" \
|
||||
--scheduler-port 6379 \
|
||||
--scheduler-topic "test" \
|
||||
--scheduler-ttl 9000
|
||||
|
||||
```
|
||||
|
||||
**Decode Instance**
|
||||
**decode instance**
|
||||
|
||||
```bash
|
||||
export FD_LOG_DIR="log_decode"
|
||||
@@ -109,8 +227,7 @@ export $(bash scripts/get_rdma_nics.sh gpu)
|
||||
echo "KVCACHE_RDMA_NICS ${KVCACHE_RDMA_NICS}"
|
||||
python -m fastdeploy.entrypoints.openai.api_server \
|
||||
--model ERNIE-4.5-300B-A47B-BF16 \
|
||||
--port 8184 \
|
||||
--metrics-port 8185 \
|
||||
--port 8184 --metrics-port 8185 \
|
||||
--engine-worker-queue-port 8186 \
|
||||
--cache-queue-port 8187 \
|
||||
--tensor-parallel-size 4 \
|
||||
@@ -122,22 +239,23 @@ python -m fastdeploy.entrypoints.openai.api_server \
|
||||
--scheduler-host "127.0.0.1" \
|
||||
--scheduler-port 6379 \
|
||||
--scheduler-ttl 9000
|
||||
--scheduler-topic "test" \
|
||||
--splitwise-role "decode"
|
||||
|
||||
```
|
||||
|
||||
### Parameter Description
|
||||
Parameter Explanation:
|
||||
|
||||
* --splitwise-role: Specifies whether the current service is prefill or decode
|
||||
* --cache-queue-port: Specifies the cache service port for communication between prefill and decode services
|
||||
* `--splitwise-role`: Specifies whether the current service is prefill or decode.
|
||||
* `--cache-queue-port`: Specifies the cache service port used for communication between prefill and decode services.
|
||||
|
||||
#### Single-machine Parameters
|
||||
* --inner-prefill-ports: Only required for Decode instance, specifies the port list of prefill instances to connect to
|
||||
Multi-node Parameter Explanation:
|
||||
|
||||
#### Multi-machine Parameters
|
||||
* --cache-transfer-protocol: Specifies KV Cache transmission protocol, supports ipc and rdma, default is ipc
|
||||
* --scheduler-name: For PD disaggregation, set to "splitwise"
|
||||
* --scheduler-host: Redis address to connect to
|
||||
* --scheduler-port: Redis port to connect to
|
||||
* --scheduler-ttl: Specifies Redis TTL time in seconds
|
||||
* --pd-comm-port: Specifies PD communication port
|
||||
* --rdma-comm-ports: Specifies RDMA communication ports, multiple ports separated by commas, quantity should match GPU count
|
||||
* `--cache-transfer-protocol`: Specifies the KV Cache transfer protocol; supports `ipc` and `rdma`. Defaults to `ipc`.
|
||||
* `--scheduler-name`: Set to `splitwise` for PD disaggregation.
|
||||
* `--scheduler-host`: The Redis address to connect to.
|
||||
* `--scheduler-port`: The Redis port to connect to.
|
||||
* `--scheduler-ttl`: Specifies the Redis TTL (Time To Live) in seconds.
|
||||
* `--scheduler-topic`: Specifies the Redis topic.
|
||||
* `--pd-comm-port`: Specifies the PD communication port.
|
||||
* `--rdma-comm-ports`: Specifies the RDMA communication ports, separated by commas; the quantity must match the number of cards.
|
||||
|
||||